![]() | CHIMERA Lab. Spectrometry and dosimetry mobile laboratory for field researches based in the univan Mercedes Vito professionaly reconstructed and equipted for field researches |
![]() | SP-1 Low-background gamma spectrometer with NaI(Tl) detector ; 3×3″; 76SF76;(Crismatec) measurements of consentration K-40, U-238, Th-232 SP-2 Low-background gamma spectrometer with HPGe detector; PRGC 2519 (PGT); 92X ADCAM Spectrum Master low-background, high-sensitive measurements of gamma isotopes concentrations (in different environmental samples: food, building materials, air filters, etc.) |
![]() | SP-3 INSPECTOR 2000 Portable gamma spectrometer with HPGe detector (Canberra) quantitative and qualitative analyses gamma spectrometry; detector type GX4020 ;Extended Range; 40%; FWHM: (122 keV) < 1.1 keV; (1.33 MeV) < 2.0 KeV; MCA “DSA-1000”; Digital Signal Processing (DSP); GENIE 2000 Software + ISOCS + LABSOCS (Laboratory efficiency calibration software) |
![]() | SP-4 INSPECTOR 1000 Handheld radiation identifier with NaI(Tl) detector (2×2”) IPROS 2 Stabilized (Canberra) dose and count rate measurements; locating sources; nuclide identification; spectrum analysis; activity measurements; GENIE 2000 + ISOCS |
![]() | SP-5 Liquid Scintillation Counter (LSC) TRIATHLER 3 (Canberra) model BetaScout/Triathler HI-425-034; for measurements b and g isotopes; simultaneously separation alpha/beta |
![]() | Radon Calibration Chamber IFJ-KR-600; (V = 600 dm3) calibration of radon detectors within wide range of concentrations |
![]() | Professional radon monitors AlphaGUARD’s: AG-A: AlphaGUARD PQ 2000; AG-B: AlphaGUARD PQ 2000PRO; AG-C:AlphaGUARD PQ 2000PRO; AG-D:AlphaGUARD DF 2000 continuous monitoring of radon and thoron concentration (in air, soil gas, water) and weather conditions recording in measurement sites |
![]() | Radon/Thoron Gas & Decay Product Monitor EQF3220; Sarad (Germany) simultaneously detection of attached and unattached fraction of Radon daughter products; spectroscopy filter and „open face“ wire screen |
![]() ![]() | Additional accessories for AlphaGUARD’s: Multisensor Unit D/D: – differntial pressure/flow Multisensor Unit D/T: differntial pressure/temperature |
![]() | Radon WL METER measurements of indoor Radon Working Level (WL) |
![]() | AquaKit determination of radon (directly) and radium (indirectly) in water samples |
![]() | Radon/Toron progenies measurements system (WLx) (Pylon) solid state detector technology to detect alpha particles from radon and thoron progeny decay; detection range: 0.001 to 50 WL; minimum detectable level: 0.001 WL (1h continuous sample. |
![]() ![]() | RADOSYS System 2000 utomatical system for reading and counting detectors type CR-39; B&W CCD Camera, optical magnification: 100x; automatic step-motor driven 3D movement |
![]() | Radon detector RM-2 (Radon v.o.s) portable instrument for in situ measurement of soil-gas radon concentration |
![]() | Radon-JOK (Radon v.o.s) equipment for in situ permability measurements |
![]() | GammaTRACER TM WIDE TYP E (Genitron) ambient dose equivalent rate [H*(10) measuring range: 20nSv/h do 10 Sv/h GammaTRACER WIDE-XL (Genitron) photon dose equivalent rate H(X) extended sensivity and mesuring range: od 10nSv/h do 10Sv/h an autonomous measurement probe used for continuous (from 1 minute to 2 hour) surveillance of the environmental gamma dose rate. |
![]() | Ionisation chamber BabyLine 81 (Canberra) portable gamma and X-ray doserate meter/dosimeter H*(0.07) absorbed dose in human tissues under 7 mg/cm2 or 300mg/cm2 (8 keV – 10 MeV) absorbed dose (>100 mGy); dose rate (10 µGy/h -1000 mGy/h) |
![]() | RADIOMETER RKP-2 (Polon – Alfa) beta radiation and equivalent dose rate X and gamma radiation H*(10) range: 0.02 mSv/h – 2 mSv/h cintillation sonde SSA-1P ( alfa-radiation) |
![]() | Meteo station Weather Monitor II; (DAVIS) measurement and continuous monitoring: pressure, humidity, temperature, precipitation |
![]() | Radon sources (Pylon) – Rn-1025 – 21,6 kBq; 2710 mBq/min. – Rn-1025 – 52,3 kBq; 6580 mBq/min. possibility obtain given concentration of radon |
![]() | RTD Radon Transport Device; (LER IFJ PAN) device to laboratory study the transport of radon |
![]() | ExhAut; (LER IFJ PAN) automatic device for measurement of radon exhalation |
| Certified calibration gamma sources: – IAEA: RGTh-1, RGK-1, RGU-1; – mix gamma: CBSS-2 | |
![]() | SOIL MOISTURE SENSOR – ThetaProbe ML2x, Thermometer LB-710T (LABEL)) |
![]() | DIGITAL FLOW-METER GILIBRATOR-2 (Gilian) measuring range: 20-6000 ml/min |
| Laboratory accessories: Portable HV Generator: HONDA EU20i running time: 10.5 hours @ 1/4 load mechanical drill STIHL BT 360 soil probes soil samplers; sample crusher „Pulverisette 1” FRITSCH; sample slitter „Pulverisette 13” FRITSCH; drier KBC-65G (temp.: 0°C-250°C); laboratorial weighers , etc. |


























